Imágenes de páginas
PDF
EPUB

Combustible liquids-Continued

Stowage:

Passenger vessel

Required conditions for transportation-Continued

"On deck in open." "On deck under cover." "Tween decks readily accessible." "Under deck away from heat." Outside containers:

Any ICO specification container as shown in the inflammable liquids table ($146.21-100) for passenger vessels

Also:

Carboys, glass, boxed or in kegs (I00-1A, 10) not over 13 gal. сар.

Carboys, glass, boxed (ICC-1D) not over 62 gal. cap.

Steel barrels or drums (ICO-17X) STO, not over 55 gal. cap. Steel barrels or drums (ICO-170. 17E, 17H, 17X) STC, may be reused for shipment of these com bustible liquids.

Metal barrels or drums (OFO R 40) not over 110 gal. cap. Fiberboard boxes (OFO R 41) WIO. not over 90 lb gr wt. Authorized for stowage "On deck in open" only:

Portable tanks (ICC-51) not over 20,000 lb. gr. wt.

Ferry vessel, passenger or vehicle

Ferry stowage (AA).
Outside containers.

Any 100 specification container
as shown in the inflammable
liquids table ($146.21-100) for
ferry vessels.
Also:

Carboys, glass; boxed or in kegs
(I00-1A, 10) not over 13 gal.

cap.

Carboys, glass; boxed (ICC-1D) not over 6 gal. cap. Steel barrels or drums (ICO-17X) STO, not over 55 gal. cap. Steel barrels or drums (ICO-170, 17E, 171, 17X) STC. may be reused for shipment of these combustible liquids.

Metal barrels or drums (CFC R 40) not over 110 gal cap. Fiberboard boxes (CFOR 41) WIO, not over 90 lb. gr. wt. Tank motor vehicles (complying with ICO motor carrier regulations).

Portable tanks (ICC-51) not over 20,000 lb. gr. wt.

[blocks in formation]

Carboys, glass; boxed or in kegs (I00-1A, 10) not over 13 gal. сар.

Carboys, glass; boxed (ICC-1D) not over 612 gal. cap.

Steel barrels or drums (ICC-17X) STO, not over 55 gal. cap. Steel barrels or drums (ICC-170, 17E, 17H, 17X) STO, may be reused for shipment of these com bustible liquids.

Metal barrels or drums (CFO R 40) not over 110 gal. cap. Fiberboard boxes (OFOR 41) WIO, not over 90 lb. gr. wt. Tank motor vehicles (complying with 100 motor carrier regulations).

Portable tanks (ICC-51) not over 20,000 lb. gr. wt.

Tank cars complying with ICO rail carrier regulations.

Stowage:

"

"On deck in open." "On deck under cover.' "Tween decks readily accessible.' Outside containers:

Any ICC specification container
as shown in the inflammable
liquids table ($146.21-100) for
passenger vessels.
Also:

Carboys, glass; boxed or in kegs
(ICČ-1A, 1C) not over 13 gal.
сар.

Carboys, glass; boxed (ICC-1D) not over 61⁄2 gal. cap. Steel barrels or drums (ICC-17X) STC, not over 55 gal. cap. Steel barrels or drums (ICC-17C, 17E, 17H, 17X) STC, may be reused for shipment of these combustible liquids.

Metal barrels or drums (CFC R 40) not over 110 gal. cap. Fiberboard boxes (CFC R 41) WIC, not over 90 lb. gr. wt. Authorized for stowage "On deck in open" only: Portable tanks (ICC-51) not over 20,000 lb. gr. wt.

Ferry stowage (AA). Outside containers: Any ICC specification_container as shown in the inflammable liquids table ($146.21-100) for ferry vessels.

Also: Carboys, glass; boxed or in kegs (ICC-1A, 1C) not over 13 gal.

cap.

Carboys, glass; boxed (ICC-1D) not over 612 gal. cap.

Steel barrels or drums (ICC-17X) STC, not over 55 gal. cap. Steel barrels or drums (ICC-17C, 17E, 17H, 17X) STC, may be reused for shipment of these combustible liquids.

Metal barrels or drums (CFC R 40) not over 110 gal. cap. Fiberboard boxes (CFOR 41) WIC, not over 90 lb. gr. wt. Tank motor vehicles (complying with ICC motor carrier regulations).

Portable tanks (ICC-51) not over 20,000 lb. gr. wt.

Ferry stowage (BB).
Outside containers:

Any ICC specification container as shown in the inflammable liquids table ($146.21-100) for car ferries.

Also:

Carboys, glass; boxed or in kegs (ICC-1A, 1C) not over 13 gal. cap. Carboys, glass; boxed (ICC-1D) not over 6 gal. cap.

Steel barrels or drum (ICC-17X) STC, not over 55 gal. cap. Steel barrels or drums (ICC-170, 17E, 17H, 17X) STC, may be reused for shipment of these combustible liquids.

Metal barrels or drums (CFC R 40) not over 110 gal. cap. Fiberboard boxes (CFC R 41) WIC, not over 90 lb. gr. wt. Tank motor vehicles (complying with ICC motor carrier regulations). Portable tanks (ICC-51) not over 20,000 lb. gr. wt.

Tank cars complying with ICO rail carrier regulations.

[blocks in formation]

Combustible liquids, N, O; S............. May be any liquid classifying as a com

bustible liquid in accordance with the
definition contained in this subpart pro-
vided such combustible liquid is not other-
wise specified by name herein.

Outside containers shall be marked
"Combustible liquid".

[blocks in formation]

Combustible liquids—Continued

Stowage.

Passenger vesse

"On deck in open."

Required conditions for transportation-Continued

"On deck under cover." "Tween decks readily accessible." "Under deck away from heat." Outside containers:

Any ICO specification_container as shown in the inflammable liquids table ($146.21-100) for passenger vessels.

Also:

Carboys, glass; boxed or in kegs (100-1A. 10) not over 13 gal. cap.

Carboys, glass; boxed (100-1D) not over 6 gal. cap.

Steel barrels or drums (ICO-17X)
STC, not over 55 gal. cap.
Steel barrels or drums (I00-170,

17E, 17H, 17X) STC, may be reused for shipment of these combustible liquids.

Metal barrels or drums (OFC R 40) not over 110 gal. cap. Fiberboard boxes (OFO R 41) WIO. not over 90 lb. gr. wt Authorized for stowage "On deck in open" only:

Portable tanks (ICC-51) not over 20,000 lb. gr. wt.

Stowage:

"On deck in open. "On deck under cover.' "Tween decks readily accessible.” Outside containers:

Any ICC specification container

as shown in the inflammable liquids table ($146.21-100) for passenger vessels

Also:

Steel barrels or drums (ICC-17X) STC, not over 55 gal. cap. Steel barrels or drums (ICC-170, 17E, 17H, 17X) STC, may be re used for shipment of these combustible liquids.

Metal barrels or drums (OFO R 40) not over 110 gal. cap. Authorized for stowage "On deck in open" only:

Portable tanks (ICC-51) not over 20,000 lb. gr. wt.

Stowage:

"On deck in open." "On deck under cover." "Tween decks readily accessible." Outside containers:

Any ICC specification container as shown in the inflammable liquids table (§ 146.21-100) for passenger vessels. Also:

Steel barrels or drums (ICC-17X) STC, not over 55 gal. cap. Steel barrels or drums (ICC-17C, 17E, 17H, 17X) STC, may be reused for shipment of these combustible liquids.

Metal barrels or drums (CFC R 40) not over 110 gal. cap. Authorized for stowage "On deck in open" only: Portable tanks (ICC-51) not over 20,000 lb. gr. wt.

Ferry vessel, passenger or vehicle

Ferry stowage (AA).
Outside containers:

Any IOC specification_container as shown in the inflammable liquids table ($146.21-100) for ferry vessels.

Also:

Carboys, glass; boxed or in kegs (I00-1A. 10) not over 13 gal.

cap.

Carboys, glass; boxed (ICC-1D) not over 6 gal. cap. Steel barrels or drums (ICO-17X) STO, not over 55 gal. cap. Steel barrels or drums (IOC-170, 17E, 17H, 17X) STC, may be reused for shipment of these combustible liquids.

Metal barrels or drums (CFO R 40) not over 110 gal. cap. Fiberboard boxes (CFO R 41) WIC, not over 90 lb. gr. wt. Tank motor vehicles (complying with ICC motor carrier regulations)

Portable tanks (ICC-51) not over 20,000 lb. gr. wt.

[blocks in formation]
[blocks in formation]

Carboys, glass; boxed or in kegs (100-1A, 10) not over 13 gal. cap. Carboys, glass; boxed (100-1D) not over 61⁄2 gal. cap.

Steel barrels or drums (100-17X) STC, not over 55 gal. cap. Steel barrels or drums (ICO-170, 17E, 17H, 17X) STC, may be reused for shipment of these com. bustible liquids.

Metal barrels or drums (CFC R 40) not over 110 gal. cap. Fiberboard boxes (CFOR 41) WIC, not over 90 lb. gr. wt. Tank motor vehicles (complying with ICC motor carrier regulations)

Portable tanks (ICC-51) not over 20,000 lb. gr. wt.

Tank cars complying with ICC rail carrier regulations.

Ferry stowage BB).
Outside containers:

Any ICC specification container as shown in the inflammable liquids table (§146.21-100) for car ferries.

Also:

Steel barrels or drums (ICO-17X) STC, not over 55 gal. cap.

Steel barrels or drums (ICO-170, 17E, 17H, 17X) STO, may be reused for shipment of these combustible liquids.

Metal barrels or drums (CFC R 40) not over 110 gal. cap. Tank motor vehicles (complying with ICO motor carrier regulations).

Portable tanks (ICC-51) not over 20,000 lb. gr. wt.

Tank cars complying with ICO rail carrier regulations. Ferry stowage (BB). Outside containers:

Any ICC specification container as shown in the inflammable liquids table (§ 146.21-100) for car ferries.

Also:

Steel barrels or drums (ICC-17X) STC, not over 55 gal. cap. Steel barrels or drums (ICC-170, 17E, 17H, 17X) STC, may be reused for shipment of these com. bustible liquids.

Metal barrels or drums (CFC R 40) not over 110 gal. cap. Tank motor vehicles (complying with ICC motor carrier regula. tions). Portable tanks (ICC-51) not over 20,000 lb. gr. wt.

Tank cars complying with ICC rail carrier regulations.

[blocks in formation]

Compounds, lacquer, paint, or varnish, etc., removing, reducing, or thinning.

Lacquer removing, reducing, and thinning compounds.

Paint, lacquer, and varnish removing, reducing or thinning compounds. Petroleum spirits.

Removing compounds, paint varnish, lacquer, etc. Reducing compounds, paint, varnish, lacquer, etc. Solvent, mineral spirits.

Thinning compounds, paint, varnish, lacquer, etc.

Varnish remover or varnish reducer.

Varnish thinning compounds.

(When possessing a flash point at or below 150° F. and above 80° F.)

Compounds, tree or weed killing liquid (when possessing a flashpoint at or below 150° F. and above 80° F).

Removers: Compounds which through solvent or detergent action remove old paint, etc., from surfaces. Reducers: Compounds which consist of exceptionally slow-drying thinners used with pyroxylin base lacquers or enamels to retard speed of drying.

Thinners: Compounds which consist of clear liquid solvents and diluents for the reduction of primers, surfacers, and enamels to proper working consistencies. Flash points variable.

Outside containers shall be marked either with the proper shipping name (as defined in ($146.04-1), or "Combustible liquid".

Flash point variable.. Outside containers shall be marked either with the proper name or "Combustible liquid”.

[blocks in formation]

Combustible liquids-Continued

Stowage:

Passenger vessel

"On deck in open."

Required conditions for transportation-Continued

"On deck under cover." "Tween decks readily accessible." "Under deck away from heat." Outside containers:

Any ICC specification container

as shown in the inflammable liquids table (§ 146.21-100) for passenger vessels. Also:

Carboys, glass; boxed or in kegs (ICČ-1A, 1Ć) not over 13 gal.

cap.

Carboys, glass: boxed (ICC-1D) not over 612 gal. cap. Steel barrels or drums (ICC-17X) STC, not over 55 gal. cap. Steel barrels or drums (ICC-17C, 17E, 17H, 17X) STC, may be reused for shipment of these combustible liquids.

Metal barrels or drums (CFC R 40) not over 110 gal. cap. Fiberboard boxes (CFC R 41) WIC, not over 90 lb. gr. wt. Authorized for stowage "On deck in open" only:

Portable tanks (ICC-51) not over 20,000 lb. gr. wt.

Stowage:

"On deck in open."
"On deck under cover."

"Tween decks readily accessible." "Under deck away from heat." Outside containers:

Any ICC specification container
as shown in the inflammable
liquids table (§ 146.21-100) for
passenger vessels.
Also:

Carboys, glass; boxed or in kegs
(ICČ-1A, 1C) not over 13 gal.
cap.

Carboys, glass; boxed (ICC-1D)
not over 61 gal. cap.

Steel barrels or drums (ICC-17X)
STC, not over 55 gal. cap.
Steel barrels or drums (ICC-170,
17E, 17H, 17X) STC, may be re-
used for shipment of these com-
bustible liquids.

Metal barrels or drums (CFO R
40) not over 110 gal. cap.
Fiberboard boxes (CFC R 41)
WIC, not over 90 lb. gr. wt.
Authorized for stowage "On deck
in open" only:
Portable tanks (ICC-51) not
over 20,000 lb. gr. wt.

[blocks in formation]

cap.

Carboys, glass; boxed (ICC-1D) not over 61⁄2 gal. cap. Steel barrels or drums (ICC-17X) STC, not over 55 gal. cap. Steel barrels or drums (ICC-17C, 17E, 17H, 17X) STC, may be reused for shipment of these combustible liquids.

Metal barrels or drums (CFC R 40) not over 110 gal. cap. Fiberboard boxes (CFC R 41) WIC, not over 90 lb. gr. wt. Tank motor vehicles (complying with ICC motor carrier regulations).

Portable tanks (ICC-51) not over 20,000 lb. gr. wt.

Ferry stowage (AA). Outside containers: Any ICC specification_container as shown in the inflammable liquids table ($146.21-100) for ferry vessels.

Also:

Carboys, glass; boxed or in kegs (ICC-1A, 1C) not over 13 gal cap.

Carboys, glass; boxed (ICC-1D) not over 62 gal. cap.

Steel barrels or drums (ICC-17X) STC, not over 55 gal. cap. Steel barrels or drums (ICC-17C, 17E, 17H, 17X) STC, may be reused for shipment of these combustible liquids.

Metal barrels or drums (CFC R 40) not over 110 gal. cap. Fiberboard boxes (CFC R 41) WIC, not over 90 lb. gr. wt. Tank motor vehicles (complying with ICC motor carrier regulations.)

Portable tanks (ICC-51) not over 20,000 lb. gr. wt.

R. R. car ferry, passenger or vehicle

Ferry stowage (BB).
Outside containers:

Any ICC specification container as shown in the inflammable liquids table (§ 146.21-100) for car ferries.

Also:

Carboys, glass; boxed or in kegs (ICC-1A, 1C) not over 13 gal.

cap.

Carboys, glass; boxed (ICC-1D) not over 61 gal. cap.

Steel barrels or drums (ICC-17X) STC, not over 55 gal. cap. Steel barrels or drums (ICC-17C, 17E, 17H, 17X) STC, may be reused for shipment of these combustible liquids.

Metal barrels or drums (CFC R 40) not over 110 gal. cap. Fiberboard boxes (CFC R 41) WIC, not over 90 lb. gr. wt. Tank motor vehicles (complying with ICC motor carrier regula. tions).

Portable tanks (ICC-51) not over 20,000 lb. gr. wt.

Tank cars complying with ICO rail carrier regulations.

Ferry stowage (BB).
Outside containers:

Any ICC specification container as shown in the inflammable liquids table (§ 146.21-100) for car ferries.

Also:

Carboys, glass; boxed or in kegs (ICČ-1A, 1C) not over 13 gal.

cap.

Carboys, glass; boxed (ICC-1D) not over 612 gal. cap.

Steel barrels or drums (ICC-17X) STC, not over 55 gal. cap. Steel barrels or drums (ICC-17C, 17E, 17H, 17X) STC, may be reused for shipment of these com. bustible liquids.

Metal barrels or drums (CFC R 40) not over 110 gal. cap. Fiberboard boxes (CFCR 41) WIC, not over 90 lb. gr. wt. Tank motor vehicles (complying with ICC motor carrier regulations.) Portable tanks (ICC-51) not over 20,000 lb. gr. wt.

Tank cars complying with ICC rail carrier regulations.

715

« AnteriorContinuar »