| 1999 - 570 páginas
...thickness to provide a thermal conductance of not more than 0.075 Btu per square foot per degree P. differential in temperature per hour. The insulating...atmospheric temperature conditions below the pressure for wMch the tanks are designed. (b) An alternate arrangement may consist of three compressors, any two... | |
| 1969 - 612 páginas
...liquid below 90° F., at least two complete cooling plants, automatically regulated by temperature variations within the tanks shall be provided; each...the necessary auxiliaries for proper operation. The control system shall also be capable of being manually operated. An alarm shall be provided to indicate... | |
| 1983 - 390 páginas
...liquid below 90° F., at least two complete cooling plants, automatically regulated by temperature variations within the tanks shall be provided; each...the necessary auxiliaries for proper operation. The control system shall also be capable of being manually operated. An alarm shall be provided to indicate... | |
| 1985 - 396 páginas
...liquid below 90° F., at least two complete cooling plants, automatically regulated by temperature variations within the tanks shall be provided; each...with the necessary auxiliaries for proper operation. Trie control system shall also be capable of being manually operated. An alarm shall be provided to... | |
| 1970 - 626 páginas
...least two complete cooling plants, automatically regulated by temperature variations within the tanke shall be provided; each to be complete with the necessary auxiliaries for proper operation. The control system shall also be capable of being manually operated. An alarm shall be provided to indicate... | |
| United States. Coast Guard - 1977 - 1570 páginas
...liquid below 90° F., at least, two complete cooling plants, automatically regulated by temperature variations within the tanks shall be provided; each...the necessary auxiliaries for proper operation. The control system shall also be capable of being manually operated. An alarm shall be provided to indicate... | |
| United States. Coast Guard - 1966 - 712 páginas
...less than that required by paragraph (a) of this section. 98.25-35 Refrigerated systems 98.25-35(a) Where refrigerated systems are installed to maintain...maintain the vapor pressure in the tanks during the peak atmospneric temperature conditions below the pressure for which the tanks are designed. 98.25-35 (b)... | |
| United States. Congress. House. Merchant Marine and Fisheries - 1971 - 426 páginas
...complete cooling plants, automatically regulated by temperature variations within the tanks should be provided, each to be complete with the necessary auxiliaries for proper operation. The control system should also be capable of being manually operated. An alarm should be provided to indicate... | |
| 1972 - 846 páginas
...thickness to provide a thermal conductance of not more than 0.075 Btu per square foot per degree P. differential in temperature per hour. The insulating...shall be capable of maintaining the vapor pressure hi the tanks during peak atmospheric temperature conditions below the pressure for which the tanks... | |
| |