... be packed in suitable inside containers completely surrounded by a shield of lead or other suitable material of such thickness that at any time during transportation the gamma radiation at one meter (39.3 inches) from any point on the radioactive... NBS Handbook - Página 261949Vista completa - Acerca de este libro
| 1958 - 1226 páginas
...(39.3 inches) from any point on the radioactive source will not exceed 10 milliroentgens per hour. The shield must be so designed that it will not open or break under conditions incident to transportation. The minimum shielding must be sufficient to prevent the escape of any primary... | |
| 1963 - 942 páginas
...(39.3 inches) from any point on the radioactive source will not exceed 10 milliroentgens per hour. The shield must be so designed that it will not open or break under conditions incident to transportation. The minimum shielding must be sufficient to prevent the escape of any primary... | |
| 1965 - 928 páginas
...(39.3 inches) from any point on the radioactive source will not .exceed 10 milliroentgens per hour. The shield must be so designed that It will not open or break under conditions Incident to transportation. The minimum shielding must be sufficient to prevent the escape of any primary... | |
| U.S. Atomic Energy Commission - 1955 - 80 páginas
...(39.3 inches) from any point on the radioactive source will not exceed 10 milliroentgens per hour. The shield must be so designed that it will not open or break under conditions incident to transportation. The minimum shielding must be sufficient to prevent the escape of any primary... | |
| United States. Congress. Joint Committee on Atomic Energy - 1959 - 648 páginas
...sufficient shielding to meet the requirements of Subparagraphs A (4), A (5), and A (6) of this condition. The shield must be so designed that it will not open or break under normal conditions incident to transportation. D. Labeling. — Each outside container label required... | |
| U.S. Atomic Energy Commission - 1962 - 1130 páginas
...shieldiiiK to rr«|airemeii(s of Kiili|MiniKraphs A (4), A (5), and A («) of this ol •.••o. lite shield must be so designed that it will not open or break under <K*i •lAdltlons incident to transportation. «Hjt«i<V container label required under seitlon 20.203... | |
| United States Atomic Energy Commission - 1966 - 1040 páginas
...sufficient shielding to meet the requirements of subparagraphs A(4), A(5), and A(6) of this condition. The shield must be so designed that it will not open or break under normal conditions incident to transportation. D. Labeling Each outside container label required under... | |
| 1949 - 558 páginas
...(39.3 inches) from any point on the radioactive source will not exceed 10 milliroentgens per hour. The shield must be so designed that it will not open or break under conditions Incident to transportation. The minimum shielding must be sufficient to prevent the escape of any primary... | |
| 1967 - 940 páginas
...(39.3 Inches) from any point on the radioactive source will not exceed 10 milliroentgens per hour. The shield must be so designed that It will not open or break under conditions Incident to transportation. The m<"'"""" shielding must be sufficient to prevent the escape of any... | |
| |