" ... be packed in suitable inside containers completely surrounded by a shield of lead or other suitable material of such thickness that at any time during transportation the gamma radiation at one meter (39.3 inches) from any point on the radioactive... "
NBS Handbook - Página 26
1949
Vista completa - Acerca de este libro

The Code of Federal Regulations of the United States of America

1958 - 1226 páginas
...(39.3 inches) from any point on the radioactive source will not exceed 10 milliroentgens per hour. The shield must be so designed that it will not open or break under conditions incident to transportation. The minimum shielding must be sufficient to prevent the escape of any primary...
Vista completa - Acerca de este libro

The Code of Federal Regulations of the United States of America

1963 - 942 páginas
...(39.3 inches) from any point on the radioactive source will not exceed 10 milliroentgens per hour. The shield must be so designed that it will not open or break under conditions incident to transportation. The minimum shielding must be sufficient to prevent the escape of any primary...
Vista completa - Acerca de este libro

The Code of Federal Regulations of the United States of America

1965 - 928 páginas
...(39.3 inches) from any point on the radioactive source will not .exceed 10 milliroentgens per hour. The shield must be so designed that It will not open or break under conditions Incident to transportation. The minimum shielding must be sufficient to prevent the escape of any primary...
Vista completa - Acerca de este libro

Handbook of Federal Regulations Applying to Transportation of Radioactive ...

U.S. Atomic Energy Commission - 1955 - 80 páginas
...(39.3 inches) from any point on the radioactive source will not exceed 10 milliroentgens per hour. The shield must be so designed that it will not open or break under conditions incident to transportation. The minimum shielding must be sufficient to prevent the escape of any primary...
Vista completa - Acerca de este libro

Industrial Radioactive Waste Disposal: Hearings Before the Special ...

United States. Congress. Joint Committee on Atomic Energy - 1959 - 648 páginas
...sufficient shielding to meet the requirements of Subparagraphs A (4), A (5), and A (6) of this condition. The shield must be so designed that it will not open or break under normal conditions incident to transportation. D. Labeling. — Each outside container label required...
Vista completa - Acerca de este libro

Industrial Radioactive Waste Disposal: Hearings Before the ..., Volúmenes4-5

United States. Congress. Joint Committee on Atomic Energy. Special Subcommittee on Radiation - 1959 - 672 páginas
...sufficient shielding to meet the requirements of Subparagraphs A (4), A (5). and A (6) of this condition. The shield must be so designed that It will not open or break under normal conditions incident to transportation. D. Labeling. — Each outside container label required...
Vista completa - Acerca de este libro

Atomic Energy Commission Reports: Opinions and Decisions of the ..., Volumen1

U.S. Atomic Energy Commission - 1962 - 1130 páginas
...shieldiiiK to rr«|airemeii(s of Kiili|MiniKraphs A (4), A (5), and A («) of this ol •.••o. lite shield must be so designed that it will not open or break under <K*i •lAdltlons incident to transportation. «Hjt«i<V container label required under seitlon 20.203...
Vista completa - Acerca de este libro

Atomic Energy Commission reports v.2, Volumen2

United States Atomic Energy Commission - 1966 - 1040 páginas
...sufficient shielding to meet the requirements of subparagraphs A(4), A(5), and A(6) of this condition. The shield must be so designed that it will not open or break under normal conditions incident to transportation. D. Labeling Each outside container label required under...
Vista completa - Acerca de este libro

The Code of Federal Regulations of the United States of America

1949 - 558 páginas
...(39.3 inches) from any point on the radioactive source will not exceed 10 milliroentgens per hour. The shield must be so designed that it will not open or break under conditions Incident to transportation. The minimum shielding must be sufficient to prevent the escape of any primary...
Vista completa - Acerca de este libro

The Code of Federal Regulations of the United States of America

1967 - 940 páginas
...(39.3 Inches) from any point on the radioactive source will not exceed 10 milliroentgens per hour. The shield must be so designed that It will not open or break under conditions Incident to transportation. The m<"'"""" shielding must be sufficient to prevent the escape of any...
Vista completa - Acerca de este libro