The Code of Federal Regulations of the United States of AmericaU.S. Government Printing Office, 1969 The Code of Federal Regulations is the codification of the general and permanent rules published in the Federal Register by the executive departments and agencies of the Federal Government. |
Dentro del libro
Resultados 1-5 de 100
Página 137
... ends are exempt from the requirements of § 173.61 ( d ) , ( f ) , and ( g ) . Gross weight of boxes not to exceed 65 pounds . ( 2 ) Spec . 14 , 15A , or 16A ( § 178.165 , § 178.168 , or § 178.185 of this chapter ) . Wooden boxes , or ...
... ends are exempt from the requirements of § 173.61 ( d ) , ( f ) , and ( g ) . Gross weight of boxes not to exceed 65 pounds . ( 2 ) Spec . 14 , 15A , or 16A ( § 178.165 , § 178.168 , or § 178.185 of this chapter ) . Wooden boxes , or ...
Página 138
... end , except those made in compliance with spec . 23G which must be marked on the side or end , and kegs , drums , or barrels containing high ex- plosives must be marked on both ends " HIGH EXPLOSIVES - DANGEROUS " in letters not less ...
... end , except those made in compliance with spec . 23G which must be marked on the side or end , and kegs , drums , or barrels containing high ex- plosives must be marked on both ends " HIGH EXPLOSIVES - DANGEROUS " in letters not less ...
Página 139
... end , and kegs , drums , or barrels containing high ex- plosives must be marked on both ends " HIGH EXPLOSIVES DANGEROUS " in letter not less than 16 inch in height . ( c ) High explosives with no liquid ex- plosive ingredient must not ...
... end , and kegs , drums , or barrels containing high ex- plosives must be marked on both ends " HIGH EXPLOSIVES DANGEROUS " in letter not less than 16 inch in height . ( c ) High explosives with no liquid ex- plosive ingredient must not ...
Página 141
... ends of the column face toward the center of the tube . The shaped charges in the fiber tubes must fit snugly with ... ends . Gross weight not to exceed 65 pounds . Inside individual con- tainers shall be separated by means of double ...
... ends of the column face toward the center of the tube . The shaped charges in the fiber tubes must fit snugly with ... ends . Gross weight not to exceed 65 pounds . Inside individual con- tainers shall be separated by means of double ...
Página 142
... end , and kegs , drums , or barrels containing high explosives must be marked on both ends " HIGH EXPLO- SIVES DANGEROUS " in letters not less than 6 inch in height . When space will not permit such marking on ends of kegs or drums , it ...
... end , and kegs , drums , or barrels containing high explosives must be marked on both ends " HIGH EXPLO- SIVES DANGEROUS " in letters not less than 6 inch in height . When space will not permit such marking on ends of kegs or drums , it ...
Otras ediciones - Ver todas
Términos y frases comunes
acid Amdt amended by Order authorized barrels or drums blasting caps bottles boxes with inside brazing Bureau of Explosives carboys cargo tank carrier certify chap chapter chemical chime closure comply compressed gas containers as follows corrugated fiberboard cushioned cylinders dangerous articles defects devices exceed exemption Fiberboard boxes flammable gallons capacity gases gasket gauge length gross weight head hydrostatic test igniters inside containers inspection inspector label leakage least liquefied petroleum gas liquid loaded manufacture marked ments Metal barrels mixtures motor vehicle nitroglycerin NOTE offered for transportation Order 66 package packed in specification paragraph percent placards plosives polyethylene pounds per square prescribed projectiles radioactive radioactive materials rail express rated capacity retested Rolling hoops sealing device seams securely service pressure shipments shipped solid Spec specification containers square inch steel Subpart tainers tank cars tare weight test pressure threads tion trichlorosilane valve welded Wooden boxes yield strength
Pasajes populares
Página 58 - USC 203 and 205 to the same extent as If he were to serve as a full-time employee. If the estimate Is that he will serve no more than 130 days during the following 365 days, he should be carried on the rolls of the department or agency as a special Government employee and Instructed that he Is regarded as subject only to the restrictions of 18 USC 203 and 205.
Página 59 - Government employee to benefit from his performance of work under a grant or contract for which he otherwise would be disqualified because he had participated In the matter for the Government or It Is pending In an agency he has served for more than 60 days In the past year. More particularly, the provision gives the head of a department or agency the power, notwithstanding any prohibition In either 18 USC 203 or 205, to allow a special Government employee to represent before such department or agency...
Página 392 - ... necessary. Every precaution shall be taken to prevent the ignition of any flammable compressed gas from any source; and when it is possible to prevent the congregation of persons not directly concerned with the emergency, this shall be done. Every practicable precaution shall be taken to keep flames or fire away from the scene of the emergency and to prevent smoking or the lighting of pipes, cigars, or cigarettes. Similarly, special care shall be exercised in the operation of any engine, whether...
Página 202 - Parts 170-189 and 297 of this chapter. Portable tanks filled to gross weight to be shipped must be capable of withstanding a drop from a height of 4 feet onto solid concrete without rupture or serious damage, and must be equipped with lifting devices capable of holding 4 times the gross weight of filled tank.
Página 144 - The offering of nitro mannite in a dry condition for transportation by common carriers by rail freight, rail express, highway, or water, is forbidden, except as a component of manufactured articles such as percussion caps, detonators, blasting caps, and exploders, the transportation of which is authorized in this part. (b...
Página 602 - Test by dropping, filled with water to 98 percent capacity, from height of 4 feet onto solid concrete so as to strike diagonally on chime, or when without chime seam, to strike on other circumferential seam: also additional test on any other parts which might be considered weaker than the chime. <2> Hydrostatic pressure test of 40 pounds per square inch sustained for 5 minutes.