... pressure for 10 minutes if the tank is not insulated , or 20 minutes if the tank is insulated . There shall be no leakage or evidence of distress . The tank insulation and jacket need not be removed unless leakage is indicated by a drop ...
... pressure for 10 minutes if the tank is not insulated , or 20 minutes if the tank is insulated . There shall be no leakage or evidence of distress . The tank insulation and jacket need not be removed unless leakage is indicated by a drop ...
Página 113
... pressure and its permanent ex- pansion determined . Pressure must be maintained for 30 seconds and as much longer as may be necessary to secure complete expansion of the tank . Pres- sure gauge must permit reading to an accuracy of 1 ...
... pressure and its permanent ex- pansion determined . Pressure must be maintained for 30 seconds and as much longer as may be necessary to secure complete expansion of the tank . Pres- sure gauge must permit reading to an accuracy of 1 ...
Página 114
... pressure - psi Safety Safety relief valve systems relief Tank valve Up to 10 years Over 10 to 22 years Over 22 years Start to Vapor discharge tight 10 10 10 10 10 1 None G G None 10 10 1 None ( 1 ) None 10 10 10 5 100 888888888 135 25 ...
... pressure - psi Safety Safety relief valve systems relief Tank valve Up to 10 years Over 10 to 22 years Over 22 years Start to Vapor discharge tight 10 10 10 10 10 1 None G G None 10 10 1 None ( 1 ) None 10 10 10 5 100 888888888 135 25 ...
Página 115
... pressure not exceeding the marked test pressure of the tank and not less than o of the marked test pressure . If the sample disc does not burst within the prescribed limits , all discs on the car must be replaced . The hydrostatic ...
... pressure not exceeding the marked test pressure of the tank and not less than o of the marked test pressure . If the sample disc does not burst within the prescribed limits , all discs on the car must be replaced . The hydrostatic ...
Página 116
... Pressure Vessels , 1946 Edition , or the A. P. I.-A. S. M. E. Code for Unfired Pressure Vessels , 1943 Edition , may be used for the transporta- tion of liquefied compressed gas , pro- vided it fulfills all the requirements of this part ...
... Pressure Vessels , 1946 Edition , or the A. P. I.-A. S. M. E. Code for Unfired Pressure Vessels , 1943 Edition , may be used for the transporta- tion of liquefied compressed gas , pro- vided it fulfills all the requirements of this part ...
Otras ediciones - Ver todas
Términos y frases comunes
acid Amdt amended by Order authorized barrels or drums blasting caps bottles boxes with inside brazing Bureau of Explosives carboys cargo tank carrier certify chap chapter chemical chime closure comply compressed gas containers as follows corrugated fiberboard cushioned cylinders dangerous articles defects devices exceed exemption Fiberboard boxes flammable gallons capacity gases gasket gauge length gross weight head hydrostatic test igniters inside containers inspection inspector label leakage least liquefied petroleum gas liquid loaded manufacture marked ments Metal barrels mixtures motor vehicle nitroglycerin NOTE offered for transportation Order 66 package packed in specification paragraph percent placards plosives polyethylene pounds per square prescribed projectiles radioactive radioactive materials rail express rated capacity retested Rolling hoops sealing device seams securely service pressure shipments shipped solid Spec specification containers square inch steel Subpart tainers tank cars tare weight test pressure threads tion trichlorosilane valve welded Wooden boxes yield strength
Pasajes populares
Página 58 - USC 203 and 205 to the same extent as If he were to serve as a full-time employee. If the estimate Is that he will serve no more than 130 days during the following 365 days, he should be carried on the rolls of the department or agency as a special Government employee and Instructed that he Is regarded as subject only to the restrictions of 18 USC 203 and 205.
Página 59 - Government employee to benefit from his performance of work under a grant or contract for which he otherwise would be disqualified because he had participated In the matter for the Government or It Is pending In an agency he has served for more than 60 days In the past year. More particularly, the provision gives the head of a department or agency the power, notwithstanding any prohibition In either 18 USC 203 or 205, to allow a special Government employee to represent before such department or agency...
Página 392 - ... necessary. Every precaution shall be taken to prevent the ignition of any flammable compressed gas from any source; and when it is possible to prevent the congregation of persons not directly concerned with the emergency, this shall be done. Every practicable precaution shall be taken to keep flames or fire away from the scene of the emergency and to prevent smoking or the lighting of pipes, cigars, or cigarettes. Similarly, special care shall be exercised in the operation of any engine, whether...
Página 202 - Parts 170-189 and 297 of this chapter. Portable tanks filled to gross weight to be shipped must be capable of withstanding a drop from a height of 4 feet onto solid concrete without rupture or serious damage, and must be equipped with lifting devices capable of holding 4 times the gross weight of filled tank.
Página 144 - The offering of nitro mannite in a dry condition for transportation by common carriers by rail freight, rail express, highway, or water, is forbidden, except as a component of manufactured articles such as percussion caps, detonators, blasting caps, and exploders, the transportation of which is authorized in this part. (b...
Página 602 - Test by dropping, filled with water to 98 percent capacity, from height of 4 feet onto solid concrete so as to strike diagonally on chime, or when without chime seam, to strike on other circumferential seam: also additional test on any other parts which might be considered weaker than the chime. <2> Hydrostatic pressure test of 40 pounds per square inch sustained for 5 minutes.