" The conditions of the boiler and furnace in all respects should be, as nearly as possible, the same at the end as at the beginning of the test. The steam pressure should be the same, the water level the same, the fire upon the grates should be the same... "
A Textbook on Marine Engineering ...: Steam and Steam Boilers, Steam Engines ... - Página 474
por International Correspondence Schools - 1900
Vista completa - Acerca de este libro

Transactions of the American Society of Mechanical Engineers, Volúmenes1-5

American Society of Mechanical Engineers - 1884 - 658 páginas
...the same at the end as at the beginning of a test. The steam pressure and the water level should be the same. The fire upon the grates should be the same in quantity and condition, and the walls, flues, etc., should be of the same temperature. It is difficult to secure uniformity in all...
Vista completa - Acerca de este libro

Transactions, Volumen5

American Society of Mechanical Engineers - 1884 - 486 páginas
...and twenty-four hours whenever practicable. The conditions of the boiler and furnace in all respects should be, as nearly as possible, the same at the end as at the beginning of tliQ,test. The steam pressure should be the same, the water level the same, the fire upon the grates...
Vista completa - Acerca de este libro

Van Nostrand's Engineering Magazine, Volumen32

1885 - 566 páginas
...and twenty-four hours whenever practicable. 'Hie conditions of the boiler and furnace in all respects should be, as nearly as possible, the same at the...should be the same in quantity and condition, and the walls, flues, etc., should be of the same temperature. To secure as near an approximation to exact...
Vista completa - Acerca de este libro

A Manual of Steam-boilers: Their Design, Construction, and Operation

Robert Henry Thurston - 1888 - 710 páginas
...and twenty-four hours whenever practicable. The conditions of the boiler and furnace in all respects should be, as nearly as possible, the same at the end as at the beginning of the test. The steam-pressure should be the same, the water-level the same, the fire upon the grates should be the...
Vista completa - Acerca de este libro

A Treatise on Steam-boilers: Their Strength, Construction, and Economical ...

Robert Wilson - 1889 - 490 páginas
...and twenty-four hours whenever practicable. The conditions of the boiler and furnace in all respects should be, as nearly as possible, the same at the...should be the same in quantity and condition, and the walls, flues, etc., should be of the same temperature. To secure as near an approximation to exact...
Vista completa - Acerca de este libro

A Treatise on Steam-boiler: Their Strength, Construction, and Economical Working

Robert Wilson - 1889 - 492 páginas
...and twenty-four hours whenever practicable. The conditions of the boiler and furnace in all respects should be, as nearly as possible, the same at the...should be the same in quantity and condition, and the walls, flues, etc., should be of the same temperature. To secure as near an approximation to exact...
Vista completa - Acerca de este libro

A Treatise on Steam-boilers: Their Strength, Construction, and Economical ...

Robert Wilson - 1892 - 530 páginas
...and twenty-four hours whenever practicable. The conditions of the boiler and furnace in all respects should be, as nearly as possible, the same at the...beginning of the test. The steam pressure should be *he same, the water level the same, the fire upon the grates should be the same in quantity and condition,...
Vista completa - Acerca de este libro

A Handbook of Engine and Boiler Trials and of the Indicator and Prony Brake ...

Robert Henry Thurston - 1890 - 546 páginas
...and twenty-four hours whenever practicable. The conditions of the boiler and furnace in all respects should be, as nearly as possible, the same at the end as at the beginning of the test. The steam-pressure should be the same, the water-level the same, the fire upon the grates should be the...
Vista completa - Acerca de este libro

A Manual of Steam-boilers : Their Design, Construction, and Operation: For ...

Robert Henry Thurston - 1890 - 704 páginas
...and twenty-four hours whenever practicable. The conditions of the boiler and furnace in all respects should be, as nearly as possible, the same at the end as at the beginning of the test. The steam-pressure should be the same, the water-level the same, the fire upon the grates should be the...
Vista completa - Acerca de este libro

Steam-boiler Construction: A Practical Handbook for Engineers, Boiler-makers ...

Walter S. Hutton - 1891 - 544 páginas
...test, it is necessary that the water-level in the boiler and the pressure of the steani be precisely the same at the end as at the beginning of the test. A chemical analysis of the coal should be made, and its calorific value determined by calculation and...